<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Corrosion Science and Engineering Journal</title>
<title_fa>نشریه علوم و مهندسی خوردگی</title_fa>
<short_title>مهندسی خوردگی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://journal.ica.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-6417</journal_id_issn>
<journal_id_issn_online>2251-6417</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>90/3/11/1004</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1399</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2020</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>37</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تأثیر حفاظت کاتدی پالسی بر میزان برد حفاظت کاتدی در زیر پوشش‌های نواری جداشده از فولاد خطوط لوله</title_fa>
	<title>Investigation on Effect of Pulse Cathodic Protection on CP Penetration Depth Under the Tape Coating Disbondment on Pipeline Steel</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>در این پژوهش به بررسی تأثیر حفاظت کاتدی پالسی بر میزان برد حفاظت کاتدی در زیرپوشش نواری جداشده از فولاد خط لوله پرداخته&#8204;شده است و نتایج حاصله با حفاظت کاتدی به روش معمول مقایسه گردیده است. در این راستا تجهیزی که قادر به شبیه&#8204;سازی شرایط زیرپوشش جدا شده از خط لوله به طول mm2000 باشد، طراحی و ساخته شد. به&#8204;منظور بررسی تأثیر عرض شیار در میزان برد حفاظت، کوپن&#8204;های ساخته شده از جنس فولاد خط لوله API X-52 با ابعاد mm 10&amp;times;2000 وmm 50&amp;times;2000، در زیر پوشش جدا شده با فاصله mm 3 قرار گرفتند. با قرار دادن تجهیز در داخل محلول شبیه&#8204;سازی&#8204;شده خاک C2، پتانسیل mVSCE1000- به دو روش حفاظت کاتدی معمول و پالسی با فرکانس 10000 هرتز به دهانه شیار پوشش جدا شده اعمال گردید. نتایج نشان داد که با اعمال روش معمول در هر دو عرض شیار، میزان پتانسیل در همان ابتدای شیار دچار افت شده و به مقادیر OCP می&#8204;رسد در صورتی که در حفاظت پالسی بر خلاف روش معمول برد حفاظتی افزایش پیدا کرد. سطح حفاظت در شیار با عرض mm 50 بیشتر از شیار با عرض mm 10 اندازه گیری شد به گونه ای که سراسر طول جدایش در محدوده حفاظتی قرار گرفت. کم&#8204;تر بودن سطح حفاظتی در شیار با عرض mm 10 می&#8204;تواند به دلیل بالا بودن مقاومت ناشی از پلاریزاسیون غلظتی باشد که انتقال جریان مثبت به داخل شیار را محدود می&#8204;کند. همچنین مقادیر pH در اثر اعمال حفاظت پالسی در شیار با عرض mm 50 به دلیل افزایش سطح حفاظت، دارای مقادیر بالاتری نسبت به شیار با عرض mm 10 بود. به طور خلاصه نتایج نشان داد که علی رغم عدم کارایی روش حفاظت معمول در زیر پوشش جدا شده نواری، اعمال حفاظت کاتدی پالسی با فرکانس بالا می تواند به عنوان یک روش موثر در افزایش برد حفاظت کاتدی در زیر پوشش&#8204;های نواری جدا شده باشد.</abstract_fa>
	<abstract>The effect of pulse cathodic protection (CP) on CP penetration depth under&amp;nbsp; tape coating disbondment of pipeline steel&amp;nbsp; has been investigated in this&amp;nbsp; study and results have been compared with conventional CP. In this regard, a laboratory cell with the length of 2000 mm that can simulate the underlying conditions by applying CP was designed and made. For investigation of crevice width on CP penetration depth coupons with dimensions of 2000&amp;times;10 mm and 2000&amp;times;50 mm made from API X-52&amp;nbsp; pipeline steel were placed under coating disbondment with the gap size of 3 mm and different widths. By placing the cell in a simulated soil solution C2, the&amp;nbsp; potential of 1000mVSCE through&amp;nbsp; two methods of conventional &amp; pulse CP with the frequency of 10000 Hz was applied to the open mouth (OM) of the simulated coating disbondment. Result showed by applying conventional CP for both the crevice widths, potential failed sharply to Open Circuit Potential (OCP) near to the OM while for pulse CP, in contrast to conventional CP, which CP penetration depth was&amp;nbsp; increased. At the crevice with the width of 50 mm CP level was measured more than the width of 10 mm, such that the entire disbondment length was protected by CP.&amp;nbsp; The lower CP level for the crevice with the width of 10 mm could be due to concentration polarization resistance which restricted the penetration of the positive current within the crevice. Also, pH value under the coating disbondment with applying pulse CP at the crevice with the width of 50 mm was measured more than the pH value for the disbondment with 30 mm width other due to higher CP level under this disbondment. In summary, results showed despite the conventional CP, applying pulse CP with high frequency could be an effective method in increase of the CP penetration depth under tape coating disbondments.</abstract>
	<keyword_fa>خوردگی, پوشش جداشده, حفاظت کاتدی پالسی, فولاد خط لوله</keyword_fa>
	<keyword>Corrosion, Disbonded Coating, Pulse Cathodic Protection, Pipeline Steel</keyword>
	<start_page>37</start_page>
	<end_page>50</end_page>
	<web_url>http://journal.ica.ir/browse.php?a_code=A-10-1-15&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>عبدالمجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اسلامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>   m.eslami@iut.ac.ir </email>
	<code>100319475328460043</code>
	<orcid>100319475328460043</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه صنعتی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نجفی محترم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460044</code>
	<orcid>100319475328460044</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه صنعتی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>محمدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گلعذار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460045</code>
	<orcid>100319475328460045</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه صنعتی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>احمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460046</code>
	<orcid>100319475328460046</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>شرکت گاز استان اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>امین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاویان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460047</code>
	<orcid>100319475328460047</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>شرکت گاز استان اصفهان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
