<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Corrosion Science and Engineering Journal</title>
<title_fa>نشریه علوم و مهندسی خوردگی</title_fa>
<short_title>مهندسی خوردگی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://journal.ica.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-6417</journal_id_issn>
<journal_id_issn_online>2251-6417</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>90/3/11/1004</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1399</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2020</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>37</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر چیدمان  آندها در حفاظت کاتدی با استفاده از جریان اعمالی بر خوردگی بتن مسلح</title_fa>
	<title>An Investigation on the Anode Distribution in Cathodic Protection by Impressed Current on the Corrosion of Reinforced Concrete</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>در این مقاله تاثیر نحوه چیدمان آندها بر روی چگالی جریان اعمالی در سیستم حفاظت کاتدی بتن مسلح مورد بررسی قرارگرفته است. بدین منظور دو آرایش متفاوت از آندها با تعداد آندهای متفاوت مورد بررسی قرارگرفته است نتایج حاکی از آن است که محل قرارگیری آندها نسبت به میل&#8204;گردها در بتن روی چگالی جریان تاثیر مهمی دارد. و مقدار چگالی جریان اعمالی برای حفاظت از خوردگی، تابعی از محل قرارگیری آندها می&#8204;باشد. در حالتی که آندها نسبت به میل&#8204;گردها موازی می&#8204;باشند چگالی جریان اعمالی کمتری موردنیاز است و درصورتی&#8204;که آندها نسبت به میل&#8204;گردها عمودی باشند، چگالی جریان بیشتری جهت حفاظت موردنیاز می&#8204;باشد.</abstract_fa>
	<abstract>In this paper, the effect of anode arrangement is investigated on the applied current density in the cathodic protection system of reinforced concrete. For this purpose, two different arrangements of anodes with different number of anodes have been studied. The results indicate that the location of anodes relative to the rods in concrete has a significant effect on the current density. And the amount of applied current density for corrosion protection is a function of the anodes location. In the case where the anodes are parallel to the rods, a lower applied current density is required, and if the anodes are vertical to the rods, a higher current density is required for protection</abstract>
	<keyword_fa>حفاظت کاتدی, بتن مسلح, چگالی جریان,جریان اعمالی.</keyword_fa>
	<keyword>Cathodic protection, Reinforced concrete, Current density, Impressed current</keyword>
	<start_page>51</start_page>
	<end_page>64</end_page>
	<web_url>http://journal.ica.ir/browse.php?a_code=A-10-1-16&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>اسماعیل</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email> jafarias@iauhiraz.ac.ir </email>
	<code>100319475328460052</code>
	<orcid>100319475328460052</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی شیراز</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>رامین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ایازی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460053</code>
	<orcid>100319475328460053</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی شیراز</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>