<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Corrosion Science and Engineering Journal</title>
<title_fa>نشریه علوم و مهندسی خوردگی</title_fa>
<short_title>مهندسی خوردگی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://journal.ica.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-6417</journal_id_issn>
<journal_id_issn_online>2251-6417</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>90/3/11/1004</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>43</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی میدانی خوردگی سطح بیرونی لوله گاز مدفون در اثر جریان‌های القایی سرگردان DC و AC</title_fa>
	<title>Evaluation of Underground Gas
Pipeline External Corrosion Due to AC
and DC Interference Currents</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>جریان&#8204;های سرگردان ناشی از خطوط ریلی مترو (دارای جریان&#8204;های بالای DC) و خطوط انتقال برق فشارقوی هوایی (دارای جریان&#8204;های AC) یکی از معضلات مهم برای لوله&#8204;های زیرزمینی گاز درون&#8204;شهری می&#8204;باشد که بهره&#8204;برداری و نگهداری این لوله&#8204;ها را دچار مشکل نموده و هزینه&#8204;های مستقیم و غیرمستقیم خوردگی را به همراه دارد. در مطالعه پیش رو، علت خوردگی خط لوله گاز زیرزمینی تحت تاثیر جریان&#8204;های سرگردان مذکور، در یکی از مناطق تهران مورد بررسی قرار گرفته است. در ابتدا بازرسی&#8204;های میدانی در محل صورت پذیرفت و سپس بررسی&#8204;های تکمیلی آزمایشگاهی با مطالعات ریزساختاری و مورفولوژی خوردگی به انجام رسید. بر اساس نتایج حاصله، پوشش لوله و سطح بیرونی فلز در دو نقطه از خط لوله به فاصله تقریباً 10 متر از یکدیگر به&#8204;صورت موضعی آسیب دیده بودند. مطابق معیارهای استانداردی و نتایج پتانسیل AC، احتمال خوردگی شدید لوله در نقاط مذکور در اثر جریان&#8204;های سرگردان AC غیرمحتمل است. پتانسیل لحظه&#8204;ی خاموش خط لوله در هر دو نقطه دارای نوسانات بسیار شدید بود و در برخی زمان&#8204;ها مقادیر مثبت نیز مشاهده گردید؛ که بر این اساس و همچنین مطابق استاندارد مربوطه، لوله مذکور تحت تأثیر جریان&#8204;های سرگردان دینامیک DC، دچار خوردگی موضعی شدید شده است. محصولات خوردگی به&#8204;صورت غیریکنواخت سطح فلز را پوشانده و دارای ترکیبات اغلب اکسیدی و هیدروکسیدی آهن بودند. همچنین در نقطه دوم، ترکیبات آهن کلراید نیز مشاهده گردید. لذا پیشنهاد گردید مطالعات تکمیلی مطابق توصیه&#8204;های استاندارد BS EN 50162 انجام شده و سپس مطابق توصیه&#8204;های استاندارد BS EN 50122-2، در جهت رفع این معضل اقدام نمود.&lt;br&gt;
&lt;br&gt;
* شیری، مهدی -کارشناس خوردگی بازرسی فنی، شرکت گاز استان تهران، تهران، ایران&lt;br&gt;
نیازبالی، شهرام - رئیس بازرسی فنی، شرکت گاز استان تهران، تهران، ایران&lt;br&gt;
پورنیا، پیام - کارشناس ارشد بازرسی فنی، شرکت گاز استان تهران، تهران، ایران&lt;br&gt;
رکاب اسلامی، مریم - کارشناس ارشد بازرسی فنی، شرکت گاز استان تهران، تهران، ایران&lt;br&gt;
حجازی موغاری، افشین - کارشناس بازرسی فنی، شرکت گاز استان تهران، تهران، ایران</abstract_fa>
	<abstract>&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 53.54%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.908278);&quot;&gt;Adjunct to underground railway (which produce DC interference currents) and&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 64.49%; top: 53.54%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 64.9%; top: 53.54%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.892376);&quot;&gt;overhead power transmission lines&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 55.11%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.927286);&quot;&gt;(which produce AC interference currents), underground gas pipelines have been affected severely which have&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 56.69%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.911435);&quot;&gt;brought about corrosion costs namely direct and indirect costs. The effects of both types of stray currents on the&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 58.26%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.889788);&quot;&gt;UG gas pipelines located in a street in Tehran are studied. On&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 53.04%; top: 58.26%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt;-&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 53.59%; top: 58.26%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.897603);&quot;&gt;site inspections were performed and then additional&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 59.83%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.906251);&quot;&gt;laboratory studies were done to analyze and characterize the corrosion products. It is founded that the coating of&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 61.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.879657);&quot;&gt;the pipe has been disbonde&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 30.48%; top: 61.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.930932);&quot;&gt;d in two points which are in 10&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 51.39%; top: 61.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt;-&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 51.95%; top: 61.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.89618);&quot;&gt;meter distances from each other and the external pipe&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 62.96%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.912536);&quot;&gt;wall were locally corroded which has led to gas leakage. According to the standard criteria and the results of AC&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 64.55%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.958055);&quot;&gt;potential, AC interference current may not cause the cor&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 52.16%; top: 64.55%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.982604);&quot;&gt;rosion in the points. However, the amounts of off&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 87.36%; top: 64.55%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt;-&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 66.11%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.943452);&quot;&gt;potentials were out of range according to the relevant standards and therefore DC stray current produced by&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 67.68%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.920639);&quot;&gt;Tehran underground railway has mainly led to the corrosion. Corrosion products were not uniformly&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 79.67%; top: 67.68%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 80.12%; top: 67.68%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.889204);&quot;&gt;covered the&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 69.25%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.912135);&quot;&gt;metal surface and mainly contains Fe&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 37.68%; top: 69.68%; font-size: calc(var(--scale-factor)*6.48px); font-family: sans-serif;&quot;&gt;3&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 38.23%; top: 69.25%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt;O&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 39.44%; top: 69.68%; font-size: calc(var(--scale-factor)*6.48px); font-family: sans-serif;&quot;&gt;4&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 39.98%; top: 69.68%; font-size: calc(var(--scale-factor)*6.48px); font-family: sans-serif;&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 40.46%; top: 69.25%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.915271);&quot;&gt;and FeOOH as well as FeCl&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 59.54%; top: 69.68%; font-size: calc(var(--scale-factor)*6.48px); font-family: sans-serif;&quot;&gt;2&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 60.08%; top: 69.25%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.923018);&quot;&gt;. Thus, it is recommended that additional&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 70.82%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.925021);&quot;&gt;evaluations need to be done according to BS EN 50162 and afterwards, protective measures must be taken to&lt;/span&gt;&lt;br role=&quot;presentation&quot; &gt;
&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 12.38%; top: 72.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.915876);&quot;&gt;eliminate the side effects of&lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 30.92%; top: 72.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif;&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;ltr&quot; role=&quot;presentation&quot; style=&quot;left: 31.35%; top: 72.4%; font-size: calc(var(--scale-factor)*9.96px); font-family: sans-serif; transform: scaleX(0.911584);&quot;&gt;the DC stray current.&lt;/span&gt;</abstract>
	<keyword_fa>لوله‌های زیرزمینی گاز, خطوط ریلی مترو, خطوط انتقال برق فشارقوی, خوردگی جریان‌های سرگردان AC و DC.</keyword_fa>
	<keyword>Underground Gas Pipelines, Underground Railways, Overhead Power Transmission Power lines, AC
& DC Corrosion</keyword>
	<start_page>75</start_page>
	<end_page>87</end_page>
	<web_url>http://journal.ica.ir/browse.php?a_code=A-10-1-156&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
</author_list>


	</article>
</articleset>
</journal>
