Determination of Corrosion Causes and Premature Failure of The Tubes of Air Cooler in ISOMAX Unit. مهندسی خوردگی 2016; 6 (21) :19-30
URL: http://journal.ica.ir/article-1-139-en.html
Abstract:   (246 Views)
In this study, causes of premature failure due to corrosion of air cooler tubes in ISOMAX unit of an oil refinery were investigated. Corrosion products and the scales formed on the surfaces of tubes were examined using x-ray diffraction and x-ray fluorescence spectroscopy. In addition, scanning electron microscopy and energy dispersive spectroscopy were employed to study the morphology of the voids and the effect of aggressive species on their growth. The results showed that two different mechanisms were responsible for failure of the tubes. Underdeposit corrosion due to formation of the scales on the interior surfaces supported by the presence of ammonium bisulfide salts and high amounts of oxygen played a significant role in pitting corrosion on one of the tubes. On the other hand, erosion-corrosion due to high fluid velocity was the major failure mechanism in the other two tubes.
Full-Text [PDF 1757 kb]   (199 Downloads)    
Type of Study: Research | Subject: General
Received: 2022/11/25 | Accepted: 2016/10/1 | Published: 2016/10/1

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Corrosion Sciences and Engineering

Designed & Developed by : Yektaweb